BTU or Watts? How to Read Radiator Heat Output When Datasheets Mix Units — and ΔT Changes the Number
Radiator heat output is quoted in different units — watts (W), BTU per hour (BTU/h) or kilocalories per hour (kcal/h) — and the conversions are fixed: 1 W is about 3.412 BTU/h, and 1 kcal/h is about 1.163 W. But the unit is the easy part. The number itself only means something once you know the ΔT (the temperature difference between the radiator and the room) it was measured at. The same radiator rated at ΔT50 will show a much higher output than at ΔT30. So before you compare two quotes, convert them to the same unit and confirm they are quoted at the same ΔT — otherwise you are comparing numbers that were never measured the same way.
One of the quietest ways a radiator quote goes wrong is unit confusion. A buyer sourcing across markets sees one datasheet in watts, another in BTU/h, a third — often from an older Russian or Central Asian source — in kcal/h, and a fourth that quotes a big, flattering output without saying at what ΔT it was measured. As a family-run manufacturer in Tianjin that has made steel panel and steel column radiators since 2002, exporting to Europe, Russia and Central Asia, we are asked to "match" competitor outputs almost every week — and more often than not the gap is not the radiator, it is the units and the ΔT. Here is how to read an output figure correctly, convert between the units buyers actually encounter, and put every quote on the same footing before you choose.
The units, and how to convert between them Heat output is a rate of energy — energy per unit time — so every unit measures the same physical thing, just on a different scale. The three you will meet are the watt (W, the SI unit, standard across EN 442 datasheets and most of Europe), the BTU per hour (BTU/h, common in UK and US-influenced specs and in some merchant catalogs), and the kilocalorie per hour (kcal/h, still seen in older Russian, post-Soviet and Central Asian documentation). The conversions are exact and worth keeping to hand: 1 W = 3.412 BTU/h, so to go from watts to BTU/h you multiply by about 3.412; 1 kcal/h = 1.163 W, so a figure in kcal/h multiplied by 1.163 gives watts. A radiator quoted at 1,000 W is the same as roughly 3,412 BTU/h or about 860 kcal/h — identical heat, three different numbers. When a competitor's output "looks higher," the first check is always whether you are comparing watts with BTU/h, because the BTU/h figure is more than three times larger for exactly the same radiator.
Why ΔT matters more than the unit Converting units is arithmetic; the real trap is ΔT. A radiator's output is not a fixed property — it depends on how much hotter the radiator surface is than the room air, expressed as ΔT (delta-T). EN 442, the European standard, rates radiators at **ΔT50** (a mean water temperature 50 °C above room temperature, roughly 75 °C flow / 65 °C return into a 20 °C room). Lower-temperature systems — condensing boilers run cool, and heat pumps especially — operate at a much smaller ΔT, which is why the same radiator gives far less heat at ΔT30 than its ΔT50 nameplate suggests (see [understanding EN 442, ΔT50 and ΔT30](/en/blog/understanding-en442-dt50-dt30) and [radiators for heat pumps](/en/blog/low-temperature-radiators-heat-pumps)). The output falls by roughly a power-law factor as ΔT drops, so a radiator rated, say, 1,500 W at ΔT50 may deliver only around half of that at ΔT30. The lesson for a buyer: a bigger output number is meaningless unless you know the ΔT behind it. A supplier quoting at ΔT50 and one quoting at ΔT30 can print very different figures for the identical radiator — and the ΔT30 figure, though it looks worse, may be the more honest one for a heat-pump project.
Sizing: matching output to the room, not the catalog Units and ΔT are about reading a quote; sizing is about choosing the right output in the first place. The output you need is set by the room's heat loss — its size, insulation, glazing, exposure and the climate it sits in — not by picking the biggest radiator that fits the wall. Calculate the room's heat demand, then choose a radiator whose output at your system's actual ΔT meets or slightly exceeds it (our room-by-room method is in [how to calculate radiator output per room](/en/blog/calculate-radiator-output-per-room)). Two consequences follow. First, in a low-temperature or heat-pump system you must size against the ΔT30 output, not the ΔT50 nameplate — which usually means a larger surface, a Type 22 or 33 panel rather than a Type 11 (see [choosing steel panel radiator types](/en/blog/steel-panel-radiator-types-how-to-choose)). Second, oversizing "to be safe" has a cost: an oversized radiator overshoots and makes room controls like TRVs work harder, so match the output, do not inflate it.
Putting every quote on the same footing When you receive outputs from several suppliers, normalize before you compare. Convert everything to a single unit — watts is the cleanest, since it is the EN 442 base — and confirm every figure is quoted at the same ΔT; if a datasheet does not state the ΔT, ask, and treat a refusal to say as a warning sign. Then check the output against your room heat-loss calculation at your system's real operating ΔT, not the catalog's headline ΔT50. Done this way, a quote stops being a single impressive-looking number and becomes a like-for-like figure you can trust. A good factory will give you the output table at both ΔT50 and ΔT30 and state the standard it is measured to — that transparency is itself a sign of a real manufacturer, the kind of document chain we cover in [how to read a Declaration of Performance](/en/blog/reading-declaration-of-performance-steel-panel-radiators).
What we make, and how we quote output
JD Radiator (Tianjin Jiuding Yangguang HVAC Co., Ltd.) is a family-run manufacturer since 2002, supplying steel panel radiators (Type 11 / 22) and steel column radiators (the JDGZ series) to project buyers across Europe, Russia and Central Asia. We rate our radiators to EN 442, with a Declaration of Performance available, CE held and GOST documentation provided for the Russian market — all under Tianjin Jiuding Yangguang HVAC Co., Ltd. When we quote heat output we state the unit and the ΔT, and we are happy to provide outputs at both ΔT50 and ΔT30 so you can size for a conventional boiler or a low-temperature / heat-pump system on the same datasheet, and convert to BTU/h or kcal/h if your market works in those units. Send us your rooms with their heat-loss figures and your system's flow and return temperatures, and we will quote radiators whose output you can compare against any other supplier on a like-for-like basis: lunan@jdradiator.com / kevin@jdradiator.com, +86-22-69189950, or www.jdradiator.com. For documents and common questions, see our Credentials and FAQ pages, and the full range at Products.