Jiuding
JIUDINGRADIATOR
← Back to Blog

How to Compare Quotes from Steel Panel Radiator Suppliers: Making Sure You Are Comparing Like for Like

A radiator quote that looks cheaper is not always cheaper. Two suppliers can quote the same room list and arrive at very different numbers because they are rating the output differently, specifying different steel and coating, quoting different Incoterms, or leaving out documents and packaging that you will have to pay for later. Before you pick a supplier, normalize the quotes so you are genuinely comparing like for like. As a family-run manufacturer in Tianjin that has made steel panel and steel column radiators since 2002, supplying project buyers across Europe, Russia and Central Asia, we see buyers caught out by the same gaps every season — here is how to read the quotes properly.

Start with the output rating and the ΔT The first thing to check is not the price but the heat output — and the ΔT it was rated at. A radiator quoted at a higher ΔT (for example ΔT50 under EN 442) will show a bigger output number than the same radiator quoted at a lower ΔT, even though it is physically identical. If one supplier quotes to EN 442 ΔT50 and another quotes an unstated or lower ΔT, the outputs are not comparable and neither are the prices per watt. Put every quote onto the same basis: same ΔT, same rating standard, same units (see [BTU or watts and how ΔT changes the number](/en/blog/btu-vs-watts-radiator-heat-output-specifications) and [understanding EN 442 ΔT50/ΔT30](/en/blog/understanding-en442-dt50-dt30)). A quote that cannot tell you the ΔT behind its output figure is a warning sign, not a bargain.

Line up the specification, not just the type Type 11, 21, 22 or 33 is only the start. Two quotes for "Type 22" can differ in steel grade and panel thickness, in the coating system (pre-treatment, primer and powder topcoat versus a thinner finish), and in the working and test pressure the radiator is built to. These differences do not show up in the headline price but they decide how the radiator performs and how long it lasts (see [what steel and what coating, and how to verify it](/en/blog/steel-grade-coating-spec-panel-radiators-what-to-verify)). Ask each supplier to state the steel grade, the panel and convector-fin thickness, the coating system and the rated working and test pressure, then compare those lines side by side before you compare money.

Price the documents, packaging and Incoterms in A low ex-works line can hide costs that land on you later. Confirm which documents are included — a Declaration of Performance carrying the EN 442 rating, pressure-test records, EN 10204 material certificates, and GOST documentation if you are shipping to Russia or Central Asia (see [what documents come with a shipment](/en/blog/shipping-documents-steel-panel-radiator-import-order)). Confirm the export packaging — corner protection, moisture film, carton and palletization — because a quote that skimps on packaging costs you in transit damage. And compare on the same Incoterm: an FOB price and a DAP price are not the same number, because one includes freight, insurance and delivery and the other does not (see [Incoterms for radiator imports](/en/blog/incoterms-steel-radiator-imports-fob-cif-dap)). Normalize every quote to the same delivery point before you rank them.

Weigh lead time, MOQ and who you are buying from The last column is not price at all. A quote with a short, honest lead time that lands your radiators before the heating season is worth more than a slightly cheaper one that misses the window (see [when to order and the procurement calendar](/en/blog/when-to-order-steel-panel-radiators-heating-season-calendar)). Check the minimum order and whether a mixed container suits your room list (see [MOQ and mixed containers](/en/blog/minimum-order-quantity-steel-panel-radiators-mixed-container)), and check who you are actually buying from — a factory that can self-issue a DoP and show its own test records, or a trader quoting someone else's product. The right quote is the one that is complete, comparable and backed by a supplier who can stand behind the documents.

How we quote, and what we put in writing

JD Radiator (Tianjin Jiuding Yangguang HVAC Co., Ltd.) is a family-run manufacturer since 2002, supplying steel panel radiators (Type 11 / 22) and steel column radiators (the JDGZ series) to project buyers across Europe, Russia and Central Asia. We quote output to EN 442 with the ΔT stated, set out the steel grade, thickness, coating system and rated pressures, and confirm the documents — Declaration of Performance with the EN 442 rating, pressure-test records, material certificates, CE held and GOST documentation for the Russian market — along with export packaging, Incoterm and lead time, so you can compare our quote like for like against any other. Send us your room list, the design ΔT and your delivery point, and we will come back with a quote you can line up against the rest. Reach us at lunan@jdradiator.com / kevin@jdradiator.com, +86-22-69189950, or www.jdradiator.com. For documents and common questions, see our Credentials and FAQ pages, and the full range at Products.