Steel Panel Radiator Sizes: Standard Heights, Lengths and How to Choose the Right Dimensions
Choosing a steel panel radiator is not only about the type (11, 21, 22 or 33) — it is also about the physical envelope: how tall, how long, and whether it will fit under the window or on the wall you have. Height and length are not free choices; they set how much heat the radiator can put out and how it connects to the pipework. This guide covers the standard heights and length ranges, how dimensions interact with output, what the centre distance means for connections, and how to specify size at order time rather than leaving it to the person on site.
Buyers often send us a heat-load figure and a type, then ask "what size radiator do I need?" — and the honest answer is that height and length together carry the output. As a family-run manufacturer in Tianjin that has made steel panel and steel column radiators since 2002, supplying project buyers across Europe, Russia and Central Asia, we see the same thing on every project: the radiator has to satisfy the room's heat loss and fit the space, and those two constraints are what set the dimensions. Pick the dimensions badly and you either under-heat the room or order a radiator that does not fit the wall.
Standard heights — and what they are for Steel panel radiators are made in a set of common heights, typically from around 300 mm up to 900 mm, with 500 mm and 600 mm the most common for ordinary rooms. A taller radiator puts out more heat for the same length, so height is one of your two levers on output. Short heights (300-400 mm) are for long, low runs — under full-height glazing or a long window sill — where you want output spread along the wall rather than stacked up. Taller heights (600-900 mm) pack more output into a narrow wall where length is limited. The height you can use is set by the wall: the sill above, the skirting below, and the clearances the radiator needs to convect properly (see [where to position a radiator](/en/blog/where-to-position-steel-panel-radiator)).
Length, and how it trades against height Length is the second lever. For a given height and type, output rises roughly in step with length, so a 600 mm-high radiator at 1000 mm long puts out far more than the same height at 400 mm. This is why two radiators can meet the same heat load at different shapes — a long low one or a short tall one — and the right choice is the one that fits your wall. Catalog length steps are usually in fixed increments, so order to a length the factory actually makes rather than an arbitrary figure; if your wall falls between sizes, it is usually better to go one step up on length or height than to under-size. For a long or open-plan room, two smaller radiators often balance the room better than one large one in a corner.
Centre distance, depth and the connections Two more dimensions matter at order time. The depth is set by the type — a Type 11 is shallow, a Type 33 is much deeper because it packs more panels and fins — so depth follows your output and clearance choice (see [how to choose panel radiator types](/en/blog/steel-panel-radiator-types-how-to-choose)). The centre distance — the pitch between the flow and return connections — is what the pipework and valves must match; a common pitch on steel panel radiators is 50 mm, and it needs to line up with the [valves and connections](/en/blog/steel-panel-radiator-valves-connections-specifying) you are specifying. Get the centre distance and connection positions into the order so the radiator, valves and pipe centres all agree before anything is made.
Specifying size at order time — a short checklist Put the dimensions in the specification, not the renovation stage. Give the factory the room's heat loss (at the design ΔT you are working to) so output is right, then the wall constraints — maximum height under the sill and maximum length on the wall — so the radiator fits. Confirm the type (and therefore the depth) suits the clearances, and the centre distance and connection type match your valves. For [low-flow-temperature systems such as heat pumps](/en/blog/steel-panel-radiators-heat-pumps-low-flow-temperatures), remember that output falls at lower ΔT, so you may need a taller, longer or deeper radiator than a standard-temperature system would use — size for the ΔT you will actually run. Tell us the room, the wall and the ΔT, and we will come back with dimensions that fit both.
What we make, and how we size it
JD Radiator (Tianjin Jiuding Yangguang HVAC Co., Ltd.) is a family-run manufacturer since 2002, supplying steel panel radiators (Type 11 / 22) and steel column radiators (the JDGZ series) to project buyers across Europe, Russia and Central Asia. We make a range of standard heights and lengths, rate our radiators to EN 442 with a Declaration of Performance available, CE held and GOST documentation provided for the Russian market — all under Tianjin Jiuding Yangguang HVAC Co., Ltd. Send us the room's heat loss, your wall constraints and the design ΔT, and we will come back with heights, lengths, type and centre distance that meet the load and fit the space. Reach us at lunan@jdradiator.com / kevin@jdradiator.com, +86-22-69189950, or www.jdradiator.com. For documents and common questions, see our Credentials and FAQ pages, and the full range at Products.